Structural Steel
Passive protection for approved beam, column and hollow-section systems where the specified rating and tested design require spray-applied material.
Tested passive fire protection for structural elements
Survey, system selection, application, quality checks, documentation and repair support for commercial and industrial projects.
Vermiculite fire spray is a factory-formulated, spray-applied passive fire-protection material that combines lightweight mineral aggregate with a cementitious or gypsum-based binder. When installed as part of an approved tested system, the insulating layer delays temperature rise in the protected structural element during fire exposure.
It may be specified for structural steel beams and columns, decks, concrete elements or other approved substrates. Product selection depends on the required fire-resistance period, member geometry, steel section factor, critical temperature, environment, substrate, durability and tested-system limitations.
Reliance Fire Protection Systems supports surveys, specification coordination, application, inspection documentation and repair planning from Mumbai for projects across India.

Passive protection for approved beam, column and hollow-section systems where the specified rating and tested design require spray-applied material.
Underside application where permitted by the tested assembly, with careful coordination around profiles, edges, penetrations and services.
Protection or upgrading of selected concrete assemblies only where the product documentation and approved design cover the substrate and exposure.
Warehouses, factories, utility areas and process facilities requiring durable passive fire protection compatible with the operating environment.
High-rise, institutional, retail and infrastructure buildings requiring concealed or architectural fire-resistive protection.
Condition assessment and compatible reinstatement after impact, service installation, water exposure or local damage, subject to the approved system.
Confirm the product, substrate, member orientation, fire exposure, permitted thickness range and design limitations.
Review primers, galvanizing, contamination, rust, release agents and any requirement for key coat, mesh or mechanical reinforcement.
Measure installed thickness at the required locations and correct low areas using the approved application method.
Coordinate density and cohesion/adhesion verification when required by the specification, authority, manufacturer or inspection plan.
Assess humidity, water exposure, vibration, impact, air movement and whether an approved sealer, finish or higher-density system is needed.
Coordinate connections, hangers, penetrations, cladding and later services so protection continuity is not compromised.
A non-reactive insulating layer generally suited to fast coverage of complex structural profiles. Finish and durability vary by system.
A reactive coating that expands under heat. It may provide a smoother finish but has different thickness, preparation and environmental limits.
Factory-produced boards can create a boxed protection system with controlled thickness and finish, but require joint and fixing coordination.
Project support is available from Mumbai across India, subject to quantity, site access, programme, specification, approved-product availability and commercial feasibility.
It is a lightweight mineral-based sprayed fire-resistive material that insulates a protected element when installed as part of an approved tested system.
Approved applications may include steel beams, columns, decks, concrete elements and selected building services covered by the tested design.
Thickness depends on the tested system, member geometry and section factor, required rating, critical temperature, substrate and exposure. There is no universal value.
No. Vermiculite spray is normally a non-reactive insulating layer, while intumescent coating expands when heated.
Only if the approved system and manufacturer permit the exact primer or substrate and the required bond arrangement is confirmed.
Checks may cover substrate acceptance, coverage, thickness, density, adhesion or cohesion, condition, repairs and conformity with approved documents.
Yes. We support suitable project enquiries from Mumbai across Indian states and union territories, subject to project requirements.
Share structural drawings, member schedules and section factors, required fire-resistance periods, critical temperatures, substrate and primer details, environmental exposure, finish requirements, quantities, programme, inspection specification and project location.
Call +91 96999 90424 | sales@relifire.com | Contact Reliance Fire Protection Systems